(ENG) [4DDM] How 4DDM Calibration Works

  1. Run the 4DDM program on the DM/PD PC and execute Record on the Calibration Tab.                

  2. The camera (FD1 or FD10) that received the Record command performs image recording, and the PreSd PC gets the image data using RTSP communication.

  3. The video data can be converted to any video format that can be set in 4DDM. The configurable types include HEVC(H.265)/ AVC (H.264) / UHD / FHD / HD compression method and 30 or 60 FPS (Frames Per Second).

  4. Calibrate #n video data generated in 1 second increments. Specify the point of Standard Bar or Floor/Feature Point according to 2D, 3D or 2D+Position Tracking Calibration setting type.

  5. The specified data is saved in the form of Image, Point(Cal.pts.txt), Calibration Data(Cal.adj.txt) and sent to VPd or MMd.

 

※ See how to calibrate here → (ENG) [4DDM] Calibration | Step of Calibration