(ENG) Control View

The Control View Tab is a tab for centrally managing the process and version information of the client (Agent) PCs connected to the Master (Main Control) PC. It enables smooth operation of unnecessary process management tasks of PC and daemon.

PC & Process Status

Check and control the status of the PC or process connected to 4DDM.

 

  • Status

    • Display the power status of a PC with Daemon installed

      • ● LED (green): PC normal connection & process running status

      • ● LED (yellow): PC normal connection & process not running

      • ● LED (gray): PC disconnected

 

 

  • Process

    • Display the names of each daemon

 

  • System Information

    • Display the connection status of the 4D Agent installed on the Daemon PC

If the 4D Agent is less than 4.1.0.1, it will be displayed as Unknown and needs to be updated to a higher version

  • Version

    • Display daemon version information

    • If the daemon version is unknown, it is displayed as the latest version of Daemon.

 

  •   IP

    • Display the IP address of the PC where Daemon is installed

 

  •   On/Off

    • Displaying Process Execution Status

    • You can click the desired process individually to run on/off

    • Control / Storage / MMC / Vision Processor Daemon can run Process On/Off by group

 

System Information

Collects and configures information of systems connected to 4DDM.

 

  • Set DM/PD

    • Add Sub Control PC IP address to Sub PC

    • The PC currently under control cannot control the power supply, but the registered Sub PC can control the power

 

  • Get System Information all PCs

    • Update system information through the 4D Agent installed on the daemon PC

    • Update the IP address, daemon version, and Mac addresses stored in EMd in the System Information column

    • The remote PC on {WOL (Wake On Lan)} function is required for each PC where daemons are installed in advance.

 

  • System Check Setting

    • Set the communication status check interval with other connected PCs

    • Minimum 3 seconds ~ Maximum 300 seconds setting

    • Check Process On/Off status is not checked at intervals when the PC's On/Off state is set

 

Process & System Control

It controls the power and daemon processes of all systems connected to 4DDM.

  •   Turn on all daemons

    • All connected Daemon Process On

 

  •   Turn off all daemons

    • All connected Daemon Process Off

 

  •   Turn on all PCs

    • Power on all connected PCs

    • Carries Wake On LAN (WOL) signal, requires pre-setting

 

  •   Turn off all PCs

    • Power off all connected PCs

    • The PC currently under control cannot control the power supply, but the registered Sub PC can control the power

 

  •   Reboot

    • Reboot all connected PCs

    • The PC currently under control cannot control the power supply, but the registered Sub PC can control the power

 

Step of Control View

Step 1. Executing Agent Control

Step 2. Perform Start View Steps

Step 3. Select Control View > Get Info (first run, only once)

Step 4. Proceeding with PC and Process Control