Operation



OP Booth

 

 


How to On/Off Systems

  • ON

  1. Run AC (Agent Control)

  2. Grey - offline, Orange - Server turned on, Daemon not connected

  3. Click Turn on All PC

  4. Wait for Servers are Online (when turns orange, Click Refresh)

 

  1. Run DM (Device Manager)

  2. Click PoE Reboot

  3. Wait for camera on (2~3min)

  4. Check camera status (when status are not good, process camera reconnect, PoE Reboot)

  5. Run PD (Producer)

  • OFF

  1. In DM, click PoE Off to turn off camera (Click PoE and wait for message success)

  2. In AC, click Turn Off All PC


Prepare Processing

  • IF YOU USING PORTABLE CALIBRATION MONITOR YOU SHOULD CHANGE CAMERA PROPERTY TO UHD-30

  • Adjust Camera

 


Calibration process

  • Check camera status before calibration record

  • Calibration record

  • Check Images

  • Group settings

  • 2D Calibration (3-point recomended)

  • Scale reg

  • Check with preview

  • 3D Calibration

  • Set-up center points (white cross)

  • Save


Need to Check

  • Using portable monitor to adjust camera, camera property should be UHD30, 60p cause noise to calibration monitor

  • Check PreSd(10.82.5.3/4/5/6) storage(D://, E://) before shooting

  • Check MMs(10.82.5.211) storage(D://) before shooting

  • Calibration should be done before 1h before match starts

  • When match stops like half time, DON’T disconnect camera, using Save to PreStorage On/Off