(ENG) Live PD

4DLivePD refers to a separate program that directly transmits groups and channels set by the operator to the user's screen among the 4DLive streaming services. Users can view the videos of groups and channels that are set by the operator in the 4DLivePD program via mobile or the web without having to control the video directly.

4DLivePD Start View

When performing the 4DLivePD program, the first screen that pops up is the screen that shown below. In this window, the operator can directly configure the PCs to perform each Daemon independently through the IP address in the same way as 4DPD. However, it should be reminded that 4DLivePD is the same process program as 4DPD, so it cannot be run at the same time as 4DPD.

[Program Execution Steps]

  1. Check if all Daemons required for DM/PD are running and if 4DPD processes are not running.

  2. Click the 4DLivePD icon on the desktop to launch LivePD.

  3. Select LivePD Venue (Default: Multiview)

  4. Enter the Main Control PC IP address in Master PC IP (Set Control Daemon IP information is taken from the IP address registered in 4DDM)

  5. Click Connect

※ When connecting normally with an AWS instance, a CMS OK pop-up window is shown.

 

4DLivePD UI

The 4DLivePD program is in a disconnect state when the 4DLive Streaming service is not running, yet the program can be operated only when the 4DLive Streaming service is in a normal state. The following describes the basic operation of the 4DLivePD UI.

4DLivePD Status

  • Not Following / Following: When zooming in and out with the mouse wheel and is not applied to transmission in PDView, Not Following is displayed with a blue dotted line, when zooming in and out after clicking the left mouse is applied, Following is displayed with a solid red line.

  • Preview: Before converting channels, you can preview the screen of the channel you want to change, click the 'P' button next to the favorite camera icon below to preview the channel in Preview on the Preview screen.

  • Program( ) : The screen showing the transmitted channel, select the channel directly from Camera No, or click the 'P' button next to the favorite camera icon below to select the transmitted channel and display it as a red box.

  • Favorites Camera View: A window that displays the Button Layout set in Favorites Camera Settings, click the Camera number to change the channel sequentially in the nearest direction (Quick switch is when you press the Ctrl key and click the Camera number)

4DLivePD Jobs

  • Favorite Camera Setting: Detailed camera setting function for each group.

  • CH Speed: Select the preset camera switching speed set in Favorites Camera Settings, Default-Fast (0.7sec), Normal (1sec), Slow (1.5sec)

  • Camera No: Expand the list of channels in the group to Dropbox, and switch to the corresponding channel when selecting the camera number.

  • Control Mode (Connect, cannot be changed): Tracking – When selecting a group with the mouse, Drag / Click – When selecting a group with the mouse, click.

  • Data Transmission interval: Set the streaming data interval to be transmitted (Applied)

  • Zoom in: Displays the Zoom value set by the mouse wheel in the PDView.

  • Connect: The screen specified by PDView in split

 

Step of Favorites Camera Setting

 

[Camera Registration Step]

  1. Specify the channels to which PD Mode will be transmitted through the group.

  2. Check the desired Camera No (up to 10)

  3. [ > ] Apply to Favorites Cameras List with a click of a button (automatically applied to Favorite Cameras' Button Layout)

[Camera Position Setting Steps]

  1. Specify the appropriate camera number in the appropriate space from the operator's criteria.

  2. Set the location with the camera number Drag & Drop according to the actual installed camera order. list

※ Click the camera number and move to the desired location.

[Camera Switch Speed Setting Step]

  1. When moving channels sequentially from the current camera to the camera to be changed, set the travel time for each channel.

    1. Fast (shortcut F1): 0.7 seconds,

    2. Normal (shortcut F2): 1 second,

    3. Slow (shortcut F3): 1.5 seconds, can be changed as needed.

  2. If you need to apply the change value, click “Save”.

  3. Close the window [x] and then click the “Yes” button.

    1. (Wrong Way: Close the window after not applying the change value, pressing cancel and keeping the window after not applying the change value)